Supply voltage Logic circuit
|
24 V to 30 V DC (Nominal supply voltage: 24 V DC)
|
Supply voltage Power circuit
|
24 V to 30 V DC (Nominal supply voltage: 24 V DC) ( Maximum motor speed depends on voltage!)
|
Maximum current consumption Logic circuit
|
400 mA
|
|
Current consumption Power circuit (Maximum current consumption power circuit)
|
2.0 A (7.0 A) |
2.8 A (7.5 A)
|
4.1 A (10 A)
|
Duty cycle DuCy in % (load-dependent)
|
DuCy = 25 % at 100 % load torque, duty type S2 “Base time 4 minutes: Duty cycle (DuCy) = 1 minute, Break duration (BD) = 3 minutes
DuCy ≤ 50 % at reduced load torque, depending on environmental parameters and application
|
|
|
CANopen (CiA 402); PROFIBUS-DP (V0/V1); EtherCAT; IO-Link; EtherNet/IP; Modbus/TCP; POWERLINK; PROFINET IO/RT; sercos III
|
|
|
|
Nominal torque output shaft
|
5 Nm at 55 min-1 [3.69 ft • lbf at 55 r.p.m.] |
7 Nm at 55 min-1 [5.16 ft • lbf at 55 r.p.m.] |
10 Nm at 55 min-1 [7.38 ft • lbf at 55 r.p.m.]
|
|
|
Through hollow shaft dw = 20.2 mm [0.8 in]
|
|
|
|
|
|
60 mm [2.36 in]×100 mm [3.94 in]×L1 |
|
|
|
|
|
|
Resolution
|
1,000 increments per 360°
|
Measuring system detection range
|
In energized state: unlimited In de-energized state: 114 revolutions
|
|
|
|
Working temperature range
|
0 °C to +60 °C [32 °F to 140 °F]
|
|
Operating temperature range
|
-10 °C to +60 °C [14 °F to 140 °F]
|
|
Maximum relative air humidity
|
-20 °C to +85 °C [-4 °F to +185 °F]
|
|
Maximale relative Luftfeuchte
|
95 %
|
|
Condensation
|
Not permitted (condensation protection upon request)
|
|
Degree of protection
|
IP67, DIN EN 60529:2014-09, shaft sealing ring (material: FKM)
|
|
Dielectric strength
|
√ 2× 500 V DC; as per DIN EN 61439-1:2012-06
|
|
EMC
|
Electromagnetic immunity DIN EN 61000-6-1:2007-10, EN 61000-6-1:2007 DIN EN 61000-6-2:2006-03 + correction1:2011-06, EN 61000-6-2:2005 + AC:2005 IO-Link: DIN EN 61000-4-5:2019-03 (±1 kV Line-Earth/±0,5 kV Line-Line) Electromagnetic emission DIN EN 61000-6-3:2011-09 + correction1:2012-11, EN 61000-6-3:2007 + A1:2011 + AC:2012, DIN EN 61000-6-4:2011-09, EN 61000-6-4:2007 + A1:2011
|
|
Vibration resistance
|
50 m/s2 [164.04 ft/s2] (≈ 5g) @ 10 to 150 Hz; as per DIN EN 60068-2-6:2008-10
|
|
Shock resistance
|
150 m/s2 [492.13 ft/s2] (≈ 15g) @ 6 ms; as per DIN EN 60068-2-27:2010-02
|
|
Noise emission
|
Maximum 85 dB(A)
|
Data for "cULus Recognized Component” (version C)
|
cULus Recognized Component, E196161
|
UL 61800-5-1
CSA C22.2 number 274-13
|
Input voltage (power circuit) UIN
|
|
Input power (power circuit), Continuous operation
|
65 VA [0.09 hp]
|
80 VA [0.11 hp]
|
Input power (power circuit),
Duty cycle (DuCy) = 1 minute,
Break duration (BD) = 3 minutes
|
80 VA [0.11 hp]
|
100 VA [0.13 hp]
|
|
|
|
Working temperature range
|
0 °C to +55 °C [32 °F to 131 °F]
|
Operating temperature range
|
-10 °C to +55 °C [14 °F to 131 °F]
|
|
|
|
|
Conformity in accordance with
EMC Directive 2014/30/EU
Machinery Directive 2006/42/EC
|
|
|
Design C: Certification as cULus Recognized Component
|