SeGMo-Assist – GEL SEROT
Rotary sensor for the position display GEL SEPODL
- Magnetic-absolute measuring system to facilitate manual adjustment procedures
- Intended for use with the GEL SEPODL position display.
| Product | Document | Languages |
|---|---|---|
| GEL SEROT | Technical information | DE EN |
| Operating instructions | DE/EN | |
| Product information | DE/EN |
Registration required
|
Electrical data |
|
|---|---|
|
Supply voltage UB (polarity reversal protection, overvoltage protection) |
20 to 30 V DC |
|
Current consumption |
≈30 mA at 24 V DC |
|
Power consumption |
Requirements for the power supply unit: Maximum supply output: 100 VA |
|
Communication interfaces |
Internal communication interface Lenord+Bauer: RS422, proprietary transmission protocol |
|
Mechanical data |
|
|
Sensor shaft |
Durchgangshohlwelle: Edelstahl rostfrei, Durchmesser 20 H7 mm [0,79 H7 in] |
|
Maximum permissible rotational speed |
100 min-1 bei ED = 25 % (ED = Einschaltdauer) |
|
Housing material |
PA 12 schwarz |
|
Housing dimensions (not including connection elements, not including torque support) |
48 mm × 44.8 mm × 70 mm [1.89 in × 1.76 in × 2.76 in] |
|
Weight |
≈145 g [5.11 oz] |
|
Encoder data |
|
|
Scanning |
magnetic, absolute |
|
Measuring system detection range |
In energized state: unlimited In de-energized state: 129 revolutions |
|
Connection elements |
|
|
Communication interface and supply voltage |
8-pin male connector M12, A-coded |
|
Functional ground |
6.3 mm [0.25 in] flat connector |
|
Ambient data |
|
|
Operating temperature range |
0 °C to +60 °C [32 °F to 140 °F] |
|
Storage temperature range |
-20 °C to +80 °C [-4 °F to 176 °F] |
|
Maximum relative air humidity |
Condensation not permitted |
|
Degree of protection |
IP65; as per DIN EN 60529:2014-09 |
|
Dielectric strength |
500 V AC; as per DIN EN 61439-1:2012-06 |
|
EMC |
DIN EN 61326-1:2013-07; Class B device with immunity requirements for industrial environments |
|
Vibration resistance |
1 to 100 m/s2 [3.28. to 328.08 ft/s2], 5 to 15 Hz; 100 m/s2 [328.08 ft/s2], 15 to 159 Hz; as per DIN EN 60068-2-6:2008-10 |
|
Shock resistance |
800 m/s2 [2624.67 ft/s2], 6 ms, as per DIN EN 60068-2-27:2010-02 |
|
Data for "cULus Recognized Component" |
|
|
Housing type |
Closed |
|
Device function |
Process control device |
|
Connection to main power supply |
No |
|
Overvoltage category |
II |
|
Contamination level |
2 |
|
Guards |
Class III (Class SELV or PELV and limited power or LPS) |
|
Atmospheric humidity |
Maximum 80 % at temperatures up to 31 °C [87.8 °F], linear decreasing to 50 % relative atmospheric humidity at 40 °C [104 °F] |
|
Installation altitude |
≤ 2000 m [1.24 mi] |
|
Use in wet areas |
No |
|
Device mobility |
Immovable |
|
Operating conditions |
Continuous |
|
Classification according to UL61010-1 |
Type 1 |
|
Approvals |
|
|
European Economic Area |
Conformity in accordance with EMC Directive 2014/30/EU |
|
USA and Canada |
Certification as cULus Recognized Component |