Farbthema

Lenord+Bauer Finding Solutions. Founding Trust.
Visit us: IMTOF, 02.-06.04.2026, Chennai, India
Visit us: Rail Link, 09.04.2026, Dublin, Ireland
Visit us: Simtos, 13.-17.04.2026, Seoul, South Korea
Visit us: CCMT, 21.-25.04.2026, Shanghai, China, booth W5-A183
Visit us: Offshore Technology, 04.-07.05.2026, Houston, USA
Visit us: INTERPACK, 07.-13.05.2026, Düsseldorf, Germany, Packaging Valley Joint Booth
Visit us: All About Automation, 02.-03.06.2026, Hamburg, Germany
Visit us: Coiltech, 10.-11.06.2026, Novi, USA
Visit us: Automate, 22.-25.06.2026, Chicago, USA
Visit us: AMTEX, 24.-27.07.2026, Delhi, India
Visit us: Drone Days, 26.-28.08.2026, Bremen/ Oldenburg, Germany
Visit us: SMM, 01.-04.09.2026, Hamburg, Germany
Visit us: InnoTrans, 22.-25.09.2026, Berlin, Germany, hall 27, booth 561
Visit us: All About Automation, 15.10.2026, Düsseldorf, Germany
Visit us: Pack Expo, 18.-21.10.2026, Las Vegas, USA

Magnetic incremental encoder - GEL 260

for heavy duty applications

  • High-resolution magnetic incremental rotary encoders with robust mechanical design.
  • Worldwide proven technology in various applications, suitable for harsh industrial environments
  • Available with radial or axial connector or cable outlet
  • Optionally available with pressure-resistant encapsulated housing, degree of protection IP 54, ATEX approval and IECEx approval.
  • High reliability and long service life characterize the magnetic incremental encoders

Technical information

Properties

  • High resolution up to 273408 pulses per revolution
  • Interpolation up to 1024-fold
  • Optional additional current output 0 to 20 mA, 4 to 20 mA, -20 to + 20 mA
  • Reference signal
  • High electromagnetic compatibility

Advantages

  • Absolute operational reliability even in case of high humidity (condensation) and frequent change of ambient temperature
  • Withstands extreme impacts and vibration
  • Resistant to dirt and oil
  • No ageing of the magnetic sensor technology

Downloads

Downloads

Product Document Languages
GEL 260 Technical information DE EN
Technical information accessories DE EN CN
Operating instructions DE/EN

Registration required

Field of application

  • Heavy industry
  • Paper and packaging machines
  • Bottling lines
  • Transportation and storage systems
  • Machines for processing steel, wood, stone, plastics, etc.

Dimensional drawings

All dimensions in mm [inch]

Technical data

Display of signal patterns

Signal patterns T, TN

Signal patterns T; TTL level

Signal patterns U, UN

Signal patterns U; TTL level

Signal patterns S, SN

Signal patterns S; HTL level

Signal patterns V, VN

Signal patterns VN; HTL level

Signal patterns X, XN

Signal patterns XN; HTL level

 

Signal pattern

T, TN

U, UN

S, SN

V, VN

X, XN

General

Resolution (pulses per revolution)

60 to 273408

Measuring range

36° to 0,0013°

Error limit

0,07°

Measuring step deviation

0,01°

Repeatability

0,005°

Electrical data

Operating voltage

5 V DC ± 5%

10 ... 30 V DC

Power consumption

≤ 1,0 W
≤ 1,4 W

≤ 1,3 W
≤ 1,65 W

Output frequency

≤ 200 kHz

Output signal level

TTL

HTL

Output level high

≥ UB - 1,00 V
at I = 10 mA;
≥ UB - 1,20 V
at I = 30 mA

4,00 V at
I = 10 mA;
≥ 3,85 V at
I = 30 mA

≥ UB - 1,80 V at I = 10 mA;
≥ UB - 2,20 V at I = 30 mA

Output level low

≤ 0,75 V at I = 10 mA;
≤ 1,00 V at I = 30 m

≤ 1,15 V at I = 10 mA;
≤ 1,55 V at I = 30 mA

Mechanical data

Shaft diameter

6, 8, 10, 12 mm

Housing diameter

90 mm

Weight

700 g

Maximum operating speed

10,000 r.p.m.

Moment of inertia of rotor

7,5 x 10-5 kgm2

Operating torque

0,03 Ncm (< 0,1 Nm)

Starting torque

0,05 Nm (0,1 Nm)

Permissible shaft load
(Point of application 15 mm in front of flange)

200 N axial, 200 N radial

Bearing life
at max. shaft load
at half shaft load

 

2000 x 106 revolutions
12600 x 106 revolutions

Environmental conditions

Working temperature

0 °C to +70 °C(5)/ -20 °C to +85 °C (operating temperature) / -20 °C to
+85 °C (optional)

Storage temperature range

-40 °C to +105 °C

Degree of protection

IP 65, IP 64

Vibration resistance (DIN EN 600068-2-6)

100 m/s2, 10 ... 2000 Hz

Shock resistance (DIN EN 60068-2-27)

1000 m/s2, 11 ms

Electromagnetic compatibility

EN 61000-6-1 bis 4

Insulation resistance

500 V DC, > 1 MΩ

Voltage sustaining capability

500 V AC, 1 minute