SeGMo-Assist – GEL SELIN
Linear sensor for the position display GEL SEPODL
- Magnetic-absolute length measuring system to facilitatemanual adjustment procedures
- Intended for use with the GEL SEPODL position display.
| Product | Document | Languages |
|---|---|---|
| GEL SELIN | Technical information | DE EN |
| Operating instructions | DE/EN | |
| Product information | DE/EN |
Registration required
|
Electrical data |
|
|---|---|
|
Supply voltage UB (polarity reversal protection, overvoltage protection) |
20 to 30 V DC |
|
Maximum current consumption |
50 mA |
|
Communication interface |
SSI Gray |
|
Mechanical data |
|
|
Housing material |
Zinc die casting |
|
Housing dimensions (not including connectors) |
70 mm × 16 mm × 30 mm [2.76 in × 0.63 in × 1.18 in] |
|
Weight (without cable, without connector) |
≈50 g [1.76 oz] |
|
Cable data |
|
|
Cable material |
TPE-U (PUR) |
|
Cable diameter |
6.4 mm ± 0.2 mm [0.25 in ± 7.87 mil] |
|
Core cross section |
6× 0.25 mm2 [6× 24 AWG] |
|
Minimum bending radius static/dynamic |
5 ×/10 × cable diameter |
|
Connection elements |
|
|
Sensor connection |
8-pin male connector M12, A-coded |
|
Ambient data |
|
|
Operating temperature range |
-10 °C to +70 °C [+14 °F to +158 °F] |
|
Storage temperature range |
-20 °C to +85 °C [-4 °F to +185 °F] |
|
Maximum relative air humidity |
95 %, non-condensing |
|
Degree of protection |
IP 65; as per DIN EN 60529:2014-09 |
|
Dielectric strength |
500 V AC; as per DIN EN 61439-1:2012-06 |
|
EMC |
EN 61000-6-2:2005, EN 61000-6-4:2007 |
|
Vibration resistance |
1 to 100 m/s2 [3.28. to 328.08 ft/s2], 5 to 15 Hz; 1 to 100 m/s2 [3.28. to 328.08 ft/s2], 15 to 159 Hz; as per DIN EN 60068-2-6:2008-10 |
|
Shock resistance |
800 m/s2 [2624.67 ft/s2], 6 ms, as per DIN EN 60068-2-27:2010-02 |
|
Approvals |
|
|
European Economic Area |
Conformity in accordance with EMC Directive 2014/30/EU |
| Measuring system (linear sensor and magnetic tape) | |
|---|---|
| Measuring method | contactless, magnetic-absolute |
| Resolution | 10 μm [0.39 mil] |
| Maximum measuring range | 10 m [32.81 ft] |
| Maximum positioning speed | 4 m/s [8.95 mi/h] |
| Sensor distance | 1.5 mm [59.06 mil] |